Today Shengjiu Mould will talk about three way stopcock related knowledge. If you are interested, let's read on.
Principle:
The difference between the three way stopcock and the ordinary valve is that there is an outlet at the bottom. When the internal spool is in different positions, the outlets are different. For example, when the spool is at the bottom, the left and right are connected. Under the mouth. Because the left and right mouths are not on the same horizontal line. When the high-pressure heater is unloaded in an emergency, the valve is closed and the water supply is bypassed.
Classification:
The three way stopcock is divided into a converging valve and a diverging valve according to the way of fluid action. The converging valve has two inlets and flows out from one outlet after merging. The diverter valve has a fluid inlet, which flows out from two fluid outlets after being diverted.
Feature:
1. Three way stopcock has two valve cores and valve seats. The structure is similar to that of double-seat valves, but in three way stopcock, when the flow area between one valve core and valve seat increases, the flow between the other valve core and valve seat The area is reduced. In a double-seat valve, the flow area between the two valve cores and the valve seat increases or decreases at the same time.
2. The air opening and closing of the three way stopcock can only be achieved by selecting the positive and negative effects of the power machinery. In the double-seat valve, the air opening and closing can be directly achieved by reversing the valve body or valve core and the valve seat. to realise.
3. When the three-way stopcock is used in a control system that requires fluids for proportioning, since it can replace an air-on control valve and an air-off control valve at the same time, it can reduce installation costs and reduce installation space.
4. The three way stopcock can also be used in bypass control places. For example, one fluid needs to pass through the heat exchanger to exchange heat, and the other fluid does not need to pass through the heat exchanger to exchange heat. When the three way stopcock is installed in front of the heat exchanger, split flow is used Three way stopcock, when the three way stopcock is installed behind the heat exchanger, a combined three way stopcock is used. Since the liquid flowing in the three way stopcock installed in front of the heat exchanger has the same temperature, the leakage is small. The liquid flowing in the three way stopcock installed after the heat exchanger has different temperatures, which affects the valve core and valve seat The degree of expansion is different, so the leakage is larger. Generally, the temperature difference between the two liquids should not exceed 150 degrees.
If you want to know more, please contact us: laboratory plastic ware mould.